Codes | Description |
---|---|
Red LED on | Lockout - Low water pressure, Make sure pressure is above 1.5bar, reset boiler |
Red LED flashing | DHW temperature control knob in service position - Turn DHW control knob into temperature range |
Red LED flashing | Overheat - Check both overheat stats |
Yellow LED flashing | Error - Turn DHW control knob into temperature range and turn CH temperature control knob into power (reset position) and wait for minimum of 30 seconds before turning into either summer or temperature position |
Yellow LED on | Flame present on the burner |
Green LED on | Boiler ready for operation |
Green LED off | No power to boiler - Check for 230volts into the appliance, check fuse on pcb |
Green LED flashing | Boiler in stand-by - Reset position |