Fault Finding Codes
Fault finding codes for the Ultracom sxi range
Fault finding codes for the Ultracom sxi range
| Codes | Description | 
|---|---|
| F1 | Ignition fault | 
| F3 | Fan unable to reach ignition speed | 
| F4 | Ignition fault | 
| F5 | Overheat Fault | 
| F6 | Central heating flow thermistor | 
| F9 | Water pressure sensor fault, blocked flow filter or pump fault | 
| F10 | Central return flow thermistor | 
| F11 | Main board connection fault | 
| F13 | PCB memory or sensing fault | 
| F14 | Gas valve control defective | 
| F15 | E-bus voltage failure | 
| F22 | Low water pressure or ignition temperature rise too slow | 
| F25 | Circulation fault | 
| F43 | Generic error | 
| F70 | Software incompatible | 
| F73 | Unable to see pump activate | 
| F77 | Condensate pump error (optional) | 
| No display or Er | loose connection X51 | 