Boiler Service Fault Finding Codes
Fault finding codes for the Compact e range
Fault finding codes for the Compact e range
| Symtoms | Possible Faults | 
|---|---|
| No DHW | Check dhw microswitch | 
| No C/H | Check dhw microswitch if dhw demand led is lit | 
| No C/H but boiler is firing | Check divertor motor and cartridge | 
| Boiler locks out within 10 seconds | Check pump proving switch, air pressure switch and overheat stat | 
| Poor burner pressure | Check burner pressure/ignition adjustment pots on PCB | 